OLDHAM: OLCT:10N

Detection of combustible gases, toxic gases or oxygen

  • Digital technology
  • Non-intrusive calibration
  • Cost savings on wiring installation

The OLCT 10N is a digital gas detector designed for detection of the most common gases in commercial and light industrial applications. Intended for use in combination with the MX 43, the OLCT 10N provides a fast and accurate response. Up to 32 detectors can be connected on the same digital line or distributed on 8 lines. All transmitter information is received by the controller in less than 1 second.

Non-intrusive operator interface requires only a simple magnetic wand and allows one man calibration without opening the enclosure, and calibration information, such as span reserve, is stored in the MX43.

The OLCT 10N is IP65 and ATEX 3 GD certified, for use in ATEX 2 and 22 zones, and is water- and dustproof.

Range:
CH 4, C3H 8, C4H 10, H 2 : 0-100 % LEL (-20°C to + 55°C)
O2 : 0-30 % vol. (-20°C to + 50°C)
CO : 0-300 ppm / 0-1000 ppm (-20°C to + 50°C)
H2S : 0-30 ppm / 0-100 ppm (-20°C to + 50°C)
NO : 0-100 ppm / 0-300 ppm (-20°C to + 50°C)
NO2 : 0-10 ppm / 0-30 ppm (-20°C to + 50°C)
NH3 : 0-100 ppm / 0-1000 ppm (-20°C to + 40°C)
CO2 : 0-5000ppm / 0-5% vol / 0-100% vol (-40 to + 50°C)

Approvals: II 3 GD – INERIS 11ATEX3023X – IECEx 11.0029X Ex nAnC IIC T4 Gc for explosimetric versions / Ex nA IIC T4 Gc for others (except CO2 versions) Ex tc IIIC T135°C Dc -20°C<Ta<+55°C Electromagnetic compatibility according to EN50270

OLDHAM: OLCT: 20 Series

Detection of combustible gases, toxic gases or oxygen
• Intrinsically Safe (IS) and XP approved
• Small in size
• Resistant to corrosion
• Pre-calibrated sensor unit

The OLC (T) 20 Series of gas detectors aredesigned for indoor or oumonitoring and other applications totdoor facility accommodate your gas detection requirements at a reasonable price.

OLC 20 Detector
The new generation of OLC 20 combustible sensors are unaffected by poisons. The units provide extremely quick response times and complete
reliability. They can be fitted on a housing with a M25 or 3/4″ NPT thread.

OLC 20D Detector
Based on the OLC 20 sensor unit, the OLC 20D detector is equipped with a 15 m long cable (standard version) and fitting gland for direct connection to a data logger. A high-temperature version allows operation at 200°C.

New Generation: New Advantages
The stainless steel detector provides protection and resistance to corrosive agents. Classified IP 66, they are resistant to dust and water ingress. The precalibrated sensors of the OLCT 20 and OLCT 20D can be disconnected by turning the head of the unit. These “smart” sensors can be calibrated on a work bench, outside hazardous areas.Transmitter

Sensor Unit OLCT 20
The OLCT 20 sensor units, which are equipped with pre-calibrated sensors (flammable, toxic or oxygen), are classified as flameproof or intrinsically safety according to your needs or the gases detected. As in the case of the OLC 20, they are fitted on the housing by a M25 or 3/4″ NPT thread.

Detector-Transmitter OLCT 20D
Based on the OLCT 20 sensor unit, the OLCT 20D detector-transmitter is equipped with a 15 m long cable (standard version) and a packing gland for direct connection to a data-logger.

Gases Type of sensor Range (ppm) Operating Relative humidity temperature* uncondensed

  • O2 electrochemical 30,00% -20°C to +50°C 10% to 95% RH
  • CO electrochemical 100, 300 and 1000 -20°C to +50°C 10% to 95% RH
  • H2S electrochemical 30, 100 and 1000 -20°C to +50°C 10% to 95% RH
  • NO electrochemical 100, 300 and 1000 -20°C to +50°C 10% to 95% RH
  • NO2 electrochemical 10 and 30,0 -20°C to +50°C 10% to 95% RH
  • SO2 electrochemical 10,0 30,0 and 100 -10°C to +50°C 10% to 95% RH
  • Cl2 electrochemical 10,0 -20°C to +50°C 10% to 95% RH
  • H2 electrochemical 2000 -20°C to +50°C 10% to 95% RH
  • HCl electrochemical 30,0 and 100 -20°C to +40°C 10% to 95% RH
  • HCN electrochemical 10,0 and 30,0 -20°C to +40°C 10% to 95% RH
  • NH3 electrochemical 100 -20°C to +40°C 10% to 95% RH 1000 -20°C to +40°C 10% to 95% RH
  • O3 electrochemical 1,00 -10°C to +40°C 10% to 95% RH
  • PH3 electrochemical 1,00 -20°C to +40°C 10% to 95% RH
  • ClO2 electrochemical 3,00 -20°C to +50°C 10% to 95% RH
  • SiH4 electrochemical 50 -20°C to +40°C 10% to 95% RH
  • AsH3 electrochemical 1,00 -10°C to +40°C 20% to 95% RH
  • CH4 catharometer 0-100%vol -20°C to +50°C 10% to 95RH
  • H2 catharometer 0-100%vol -20°C to +50°C 10% to 95% RH
  • NH3 catalytic 0-5000 -20°C to +50°C 10% to 95% RH
  • Flammable gas catalytic 0-100% LEL -20°C to +70°C 10% to 95% RH-20°C to 200°C 10% to 95% RH

OLDHAM:OLC(T) 100: FIXED GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen

  • Infrared XP version
  • SIL 2 high reliability
  • IP 66
  • Aluminum or Stainless Steel version

The OLC/OLCT 100 range of fied detectors has been designed for detection of explosive gases, toxic gases or oxygen. At Oldham, our products are always application driven, solution-oriented. Options include:

  • OLCT 100 transmitter with 4-20 mA output
  • OLC 100 detector with a Wheatstone bridge output for detection of explosive gases.
  • Available in explosion-proof or intrinsically safe versions, the OLC (T) 100 is suitable for detection of all gases in ATEX zones.
  • The OLCT 100 is available in a stainless steel version, offering increased resistance to corrosive elements (ideal for marine, wastewater treatment
    plants, food processing activities…).
  • This stainless steel intrinsically safe version is certifid for use in zones 0 (gas) and 20 (dust), whereas all other versions of the OLCT 100 are certified for use in zones 1 (gas) and 21 (dust).

OLCT 100 XP: Explosion-proof version is equipped with a catalytic, electrochemical or semiconductor sensor, for detection of explosive, toxic gases or oxygen.

OLCT 100 IS: Intrinsically safe version is equipped with an electrochemical sensor for detection of toxic gases or oxygen.

OLCT 100 XP IR: Explosion-proof IR version is equipped with an infrared sensor for detection of CO2.

OLCT 100 XP HT: High temperature explosion-proof version for detection of explosive gases up to 200°C. High temperature cable included – 5, 10, 15 meter lengths. The OLC(T) 100 is SIL 2 certified by INERIS, according to the EN 50402 standard, which corresponds to IEC/EN 61508 for gas detectors.

(a) complete unit, according to certified INERIS No. 93664/2012
(b) software and hardware according to certified INERIS No. 93664/2012, sensors data according to proven in use
(c) O2 sensor with 28 months life expectancy

OLDHAM: Gas Detection Control Panel: MX43

  • Analog and digital controller
  • 4 or 8 lines / 16 to 32 detectors max
  • Highly versatile controller
  • Cost savings on wiring installation

The MX 43 is an analog and digital controller designed for the continuous measurement and control of the gases present in the atmosphere and for 4-20 mA or digital contact signal.
MX 43 manages both digital lines and analog channels, and covers all needs for a wide variety of applications.

The MX 43 digital technology allows up to 32 detectors to be distributed on 8 lines for increased cost savings.The USB option enables gas measurements to be saved at a sampling rate of 2 seconds to 15minutes while events are saved when they happen. The 4 Gb USB drive provides more than 2 years of storage in most of configurations. The USB option also delivers the ability to save and restore configuration and firm ware files.

OLDHAM: Gas Detection Control Panel: MX 32

1 or 2- Channel Controller Oldham has designed the MX 32, a measurement and alarm unit that is perfectly suitable for the protection of your equipment and personnel in atmospheres which may contain flammable and toxic gases. |

Available with one or two separate channels, the MX 32 offers you tailor-made detection capabilities and exceptional programming possibilities with its range of Oldham detectors. Its purchase and operating costs are enhanced by its easy installation and great operating flexibility.

  • 1 or 2 independent channels
  • 2 independent instantaneous alarm thresholds
  • Fault alarm per channel
  • Compliant with European Standards ATEX II (2) G
Simple operation

  • Liquid crystal display panel
  • Simple programming by keypad
  • “Power on” indicator lights
  • Visual alarms- 2 red LED for gas alarm thresholds per channel- 1 yellow LED for fault alarm per channelBuzzer
  • Manual or automatic acknowledgement

Easy to install

  • Small-sized wall-mounted box
  • Protected front face
  • Sealed polycarbonate box (IP 65)
  • Power supply 230 VAC or 115 VAC
    (24 VCC back-up)

Certification: ATEX 94/9/CE Directive complies with EN 50054, EN 50057, EN 50104 and EN 50271 (61779-1:2000 and 61779-4:2000 standards) Category: II (2) G Electromagnetic Compatibility: EN 50270 : 06 Types 1 and 2 Low Voltage Directive: EN 61010-1 : 10

Hooter/Beacon

The Symphoni AV provides a solution to the increasing need to incorporate visual alarms as well as sounders into fire systems.

The compact combination of LED beacon and high output Symphoni style sounder is extremely efficient making ideal for system extensions and upgrades without adding undue loading to power supplies or sounder circuits.

  • Versatile Uk & European Fire Tones
  • Ultra Low Power Consumption
  • Integrated 100db(A) Sounder & Beacon
  • Compact Design Based On The Symphoni Lockable Base
Gas Detection Control Panel